DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-736
HYB-LINE (Hybrid Line) 
10
HYB-LINE (Hybrid Line)
Hybrid Line is the user-friendly name for Hybrid Line, which was previously used 
to denote the Multifunction Analog Telephone. The Hybrid Line set is also known 
as an SCS (Small Communications System).
The TN762B Hybrid Line circuit pack supports eight of these multifunction 
analog telephone sets, as shown in the following figure. The Hybrid Line sets use 
three pairs of wires: an analog voice pair, a transmit/receive pair, and a power 
pair.
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier 
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier 
where the circuit pack is located (for example, 01, 02, ..., etc.); and pp is the 2-digit 
port number (for example, 01).
MO Name As It 
Appears in 
Alarm Log
Alarm 
Level
Initial System 
Technician 
Command to Run
1
Full Name of MO
HYB-LINE
Minor
test port PCSSpp l
Hybrid Line
HYB-LINE
Warning
test port PCSSpp l
Hybrid Line