DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-826
ISDN-TRK (DS1 ISDN Trunk) 
10
Error Log Entries and Test to Clear Values
Notes:
a. These error types indicate a disagreement between this switch and the 
switch at the other end of the trunk connection with regard to the ISDN 
call
 
state of the DS1 ISDN Trunk. This switch will automatically try to recover 
by clearing the call, (that is, the call will be torn down). You can use the 
status trunk <trunk_group/trunk_member>
 command to determine the 
state of the trunk.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the 
set options
 command. If the Minor alarm is not downgraded by the 
set options
 values, then the 
Minor alarm will be upgraded to a Major alarm if 75 percent of the trunks in this trunk group are 
alarmed.
Table 10-229.
DS1 ISDN Trunk Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
Any
None
test port PCSSpp sh r 1
15 (b)
Any
Audit and Update 
Test (#36)
18
0
busyout trunk 
<grp>/<mbr>
release trunk 
<grp>/<mbr>
129 (c)
None
WARNING
OFF
test port PCSSpp
130 (d)
None
WARNING
ON
test port PCSSpp
257 (e)
Any
None
test port PCSSpp 
513 (f)
Any
None
WARNING
OFF
test port PCSSpp 
769 (e)
Any
None
test port PCSSpp
1281
Any
Conference Circuit 
Test (#7)
MIN/ WRN
2
ON
test port PCSSpp l r 4
1537
Any
NPE Crosstalk 
Test (#6)
MIN/WRN
ON
test port PCSSpp l r 3
1793 (g)
Any
None
test port PCSSpp 
3073 (h)
Any
Service State 
Audit (#256)
test port PCSSpp
3585 (i)
Any
None
None
3841 (j)
Any
None
None