DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-889
MET-LINE (MET Line) 
10
MET Electronic Power Feed (#56)
In this test, the software requests that the EPF be turned on for a given port. An 
attempt is made to turn on the power unit to the station. If no current is being 
drawn, this probably indicates that the station is not connected. If an overcurrent 
condition is sensed (that is, too much current is being drawn), this may indicate a 
short in the loop or a defective voice terminal. Depending on what condition is 
sensed, a message is returned stating that either the EPF was turned on 
successfully with no problems or that an overcurrent condition is sensed. This 
test is repeated once more five seconds later. If either test is not successful, the 
test aborts.
Although this test will never actually return a fail result (except for the internal 
system error), an error type 257 entry will be made in the error log when the test 
has completed if the overcurrent case is detected by the hardware.
Table 10-254.
TEST #56 MET Electronic Power Feed Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
The test was aborted due to an internal system error on 
a software request to the board.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
1000
ABORT
System resources required to run this test are not 
available. The port may be busy with a valid call. Use 
the 
display port PCSSpp
 command to determine the 
station extension, attendant number, or trunk 
group/member number of the port. Use the 
status 
station
status attendant
, or 
status trunk
 command to 
determine the service state of the port. If the service 
state indicates that the port is in use, then the port is 
unavailable for certain tests. (Refer to the "Status 
Commands" section in 
 for a full 
description of all possible states.) You must wait until the 
port is idle before retesting. Attendants are always in 
use (off-hook) if the handset is plugged in and the port is 
not busied out.
1. If the port status is idle, then retry the command at 
one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page