Maintenance Object Repair Procedures 
Page 10-897
MET-LINE (MET Line) 
10
MET Line Station Lamp Updates Test (#60)
For this test, the software lights the lamps on the terminal based on the status 
record contained in the processor. The lamp updates run only if the station is 
in-service.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Check to ensure that the board translations are 
correct. Use the 
list config
 command, and resolve 
any problems that are found.
2. If the board was found to be correctly inserted in 
step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should 
re-establish the linkage between the internal ID and 
the port. If this is not the case, check to ensure that 
there is a valid board inserted.
Table 10-255.
TEST #57 MET Circuit and Conference Circuit Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation