Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-897
MET-LINE (MET Line)
10
MET Line Station Lamp Updates Test (#60)
For this test, the software lights the lamps on the terminal based on the status
record contained in the processor. The lamp updates run only if the station is
in-service.
record contained in the processor. The lamp updates run only if the station is
in-service.
0
NO
BOARD
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Check to ensure that the board translations are
correct. Use the
list config
command, and resolve
any problems that are found.
2. If the board was found to be correctly inserted in
step 1, issue the
busyout board
command.
3. Issue the
reset board
command.
4. Issue the
release busy board
command.
5. Issue the
test board long
command. This should
re-establish the linkage between the internal ID and
the port. If this is not the case, check to ensure that
there is a valid board inserted.
the port. If this is not the case, check to ensure that
there is a valid board inserted.
Table 10-255.
TEST #57 MET Circuit and Conference Circuit Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page