Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-914
MODEM-PT (Modem Pool Port) 
10
descriptions for those maintenance objects (MOs) should be consulted when 
repairing Combined Modem Pool arrangements.
Modem Pool NPE Crosstalk Test (#96)
This test is destructive.
This NPE Crosstalk Test verifies that the NPE is connected only to the desired 
time slot and is not crosstalking on other time slots. This test operates exactly like 
Test #6 for other types of port circuits but is performed twice in order to test both 
NPEs in the Modem Pool Port.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short 
Test 
Sequence
Long Test 
Sequence
D/ND
1
Modem Pool NPE Crosstalk Test (#96)
X
D
Modem Pool Conference Test (#97)
X
D
Modem Pool Conversion Resource Loop 
Around Test (#98)
X
X
ND
Modem Pool Audits Test (#99)
X
X
ND
Table 10-260.
TEST #96 Modem Pool NPE Crosstalk Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
System resources required for this test are not available.
1. Retry the command at one minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000
ABORT
System resources required to run this test are not 
available. The port may be in use on a valid call. 
Determine whether the port is available for testing.
1. Retry the command at one minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page