Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-932
MMI-BD 
10
d. Indicates transient communication problems between the switch and this 
circuit pack. Execute the 
test board PCSS
 command and refer to the 
repair procedures for the Control Channel Looparound Test (#52) in the 
XXX-BD section.
e. The circuit pack detected an Angel on-board hardware failure. The 
reported aux data values correspond to the following detected errors:
4352 - External RAM error
4253 - Internal RAM error
4355 - ROM Checksum error
4357 - Instruction set error
Reset the circuit pack by using the 
busyout board PCSS
reset board 
PCSS
, and 
release board PCSS
 commands. When reset, the circuit pack 
executes a set of tests to detect the presence of any of the above faults. 
The detection of one these errors during initialization causes the circuit 
pack to lock up and appear insane to the system. See the repair 
procedures in note b for Error Type 1.
f. This MMI circuit pack reported a loss of MMI synchronization. Refer to 
Test (#1123) for repair procedures.
g. A failure of the time slot interchanger has been detected. Reset the circuit 
pack using the 
busyout board PCSS
reset board PCSS
, and 
release 
board PCSS
 commands. If the reset passes, then the on-board circuitry is 
healthy. Retire the alarm using the 
test board PCSS long clear 
command 
followed by 
release board PCSS
h. The circuit pack is hyperactive; that is, it is flooding the switch with 
messages sent over the control channel. The circuit pack is taken out of 
service when a threshold number of these errors is reported to the switch. 
Clear the alarm using the following commands: 
busyout board PCSS
reset board PCSS
test board PCSS long clear
release board PCSS
. If 
the error recurs within 10 minutes, replace the circuit pack.
i. The TSI Cross Talk Test (#6) failed. See the description of this test and 
follow the repair procedures.
j. The TSI Looparound Test (#1108) failed. See the description of this test 
and follow the repair procedures.
System Technician-Demanded Tests: 
Descriptions and Error Code
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the TSI 
Crosstalk Test (#6), for example, you may also clear errors generated from other 
tests in the testing sequence.