Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-983
OPS-LINE (DS1 OPS Line) 
10
OPS-LINE (DS1 OPS Line)
An analog Off-Premises Station (OPS) can be connected to the system through a 
DS1 link. A TN767 DS1 Interface circuit pack supports up to 24 DS1OPSs. Since 
the DS1OPS is an analog telephone set, a channel multiplexer is necessary as 
the remote DS1 endpoint that converts the digital signal of a DS1 port to the OPS 
Line and vice versa. See 
 for details.
The DS1OPS Line Maintenance provides a strategy to maintain an OPS Line via a 
port of the DS1 Interface circuit pack. The strategy covers initialization tests, 
periodic tests, system technician-demanded tests, and alarm resolution and 
escalation. Two service states are specified in a DS1OPS Line maintenance. 
They are: 
out-of-service
 in which the line is in a deactivated state and cannot be 
used for either incoming or outgoing calls; 
in-service
 in which the line is in an 
activated state and can be used for both incoming and outgoing calls. If the DS1 
Interface circuit pack is out-of-service, then all lines on the DS1 Interface circuit 
pack are put into the out-of-service state, and a Warning alarm is raised.
For maintenance of the remote DS1 endpoint (for example, Channel Division 
Multiplexer, D4 Channel Bank), refer to the maintenance documentation from its 
vendor for details.
Figure 10-73.
DS1 OPS Line Interactions
MO Name As 
It Appears in 
Alarm Log
Alarm 
Level
Initial System 
Technician 
Command to Run
Full Name of MO
OPS-LINE
MINOR
test station <ext> l
DS1OPS Line
OPS-LINE
WARNING
test station <ext>
DS1OPS Line
CHANNEL
MULTIPLEXER
ANALOG
STATION
DS1 LINK
ANALOG
STATION
DS1
SYSTEM
"DEFINITY"
COMMUNICATIONS