Maintenance Object Repair Procedures
Page 10-989
OPS-LINE (DS1 OPS Line)
10
Conference Circuit Test (#7)
One or more NPEs reside on each circuit pack with a TDM Bus interface. The
NPE controls port connectivity and gain, and provides conferencing functions on
a per-port basis. The Conference Circuit Test verifies that the NPE channel for
the port being tested can correctly perform the conferencing function. The NPE is
instructed to listen to several different tones and conference the tones together.
The resulting signal is then measured by a Tone Detector port. If the level of the
tone is within a certain range, the test passes.
NPE controls port connectivity and gain, and provides conferencing functions on
a per-port basis. The Conference Circuit Test verifies that the NPE channel for
the port being tested can correctly perform the conferencing function. The NPE is
instructed to listen to several different tones and conference the tones together.
The resulting signal is then measured by a Tone Detector port. If the level of the
tone is within a certain range, the test passes.
Table 10-286.
TEST #7 Conference Circuit Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
System resources required for this test are not available.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000
ABORT
System resources required to run this test are not
available. The port may be in use on a valid call. Use the
available. The port may be in use on a valid call. Use the
status station
or
status trunk
command to determine
when the port is available for testing.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, and the port is not in
use, escalate the problem.
1002
ABORT
The test was aborted because the system could not
allocate time slots for the test. The system might be
under heavy traffic conditions, or it might have time slots
out of service due to TDM-BUS errors. (The
allocate time slots for the test. The system might be
under heavy traffic conditions, or it might have time slots
out of service due to TDM-BUS errors. (The
status
health
command may be used to determine whether the
system is experiencing heavy traffic.) Refer to the
TDM-BUS (TDM bus) Maintenance documentation to
diagnose any active TDM-BUS errors.
TDM-BUS (TDM bus) Maintenance documentation to
diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors, is not
handling heavy traffic, and the port status is idle,
retry the command at 1-minute intervals for a
maximum of 5 times.
retry the command at 1-minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.