Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1049
PI-BD (Processor Interface Circuit Pack) 
10
NPE Audit Test (#50)
Refer to the repair procedure described in the XXX-BD (Common Port Circuit 
Pack) Maintenance documentation as NPE Audit Test (#50).
Standby Processor Interface Circuit Pack Test 
(#423)
This test is run only in a High or Critical Reliability system. This test is run on 
Processor Interface circuit packs that are currently in Standby Mode and thus no 
active calls are up on these circuit packs. It is very important to periodically test 
the Standby Processor Interface circuit packs to ensure their health in case of an 
SPE-interchange. This test is run either by system technician demand (
test 
interface PCS
 or 
reset interface PCS
) or during scheduled maintenance. The 
test resets the circuit pack. The main purpose of this test is to perform a 
Checksum Test on the downloadable firmware or to download new Processor 
Interface firmware if the 
reset interface PCS
 command is used. If the checksum 
fails, then the firmware is downloaded again from the tape.
Table 10-303.
TEST #423 Standby PI Board Test 
Error 
Code
Test 
Result
Description/Recommendation 
9,10
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1029 
1030 
2011 
2012 
2013 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT
Refer to “STBY-SPE” for a description of these error codes.
1124
ABORT
There are currently no enabled Processor Interface links in the system.
1. Wait and run this test when links are enabled and the PI-SCI (System 
Communication Interface) has been started up.
Continued on next page