Page 10-1074
PI-SCI (System Communication Interface)
10
Error Log Entries and Test to Clear Values
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
2.
See WARNING below.
!
WARNING:
The "test interface long" command resets the PI-BD and causes all ISDN-PRI and
BX.25 links to come down.
BX.25 links to come down.
3.
Major alarms may be downgraded to Warning alarms based on the value used in the
set options
command.
Table 10-313.
PI-SCI System Communication Interface Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test interface PCS sh r 1
1 (a)
2055
2056
2057
2058
2056
2057
2058
none
none
none
none
257 (b)
Any
none
MAJOR
ON
test interface PCS l
2
769 (c)
Any
none
MAJOR/
WARNING
WARNING
3
OFF
test interface PCS l
1025 (d)
Any
none
MAJOR/
WARNING
WARNING
OFF
test interface PCS l
1281 (e)
Any
Sci Start Test (#176)
MAJOR/
WARNING
WARNING
OFF
test interface PCS l
1793 (f)
Any
none
MAJOR
ON
test interface PCS l
2049 (g)
90xx
Sci Start Test (#176)
MAJOR
ON
test interface PCS l
2305 (f)
Any
Sci Self Test (#231)
MAJOR
ON
test interface
PCS sh r 2
PCS sh r 2
2561 (h)
Any
none
MAJOR/
WARNING
WARNING
OFF
test interface PCS l
2817 (i)
Any
none
MAJOR/
WARNING
WARNING
OFF
test interface PCS l
2818 (j)
Any
none
MAJOR/
WARNING
WARNING
OFF
test interface PCS l
3073 (f)
Any
none
MAJOR/
WARNING
WARNING
OFF
test interface PCS l