Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1085
PKT-BUS (Packet Bus) 
10
The Aux Data values that indicate these sources are identified in the 
following table:
If the Aux Data value is in the range 1000-1007, then Packet circuit pack, 
port, and endpoint maintenance has been disabled in the EPN due to a 
PPN Packet Bus failure. If the value is greater than 1000, then there is also 
a failure of the packet Bus in this EPN and the source of the other 
information can be determined from the table above.
NOTE:
It is important to remember that problems reported by Packet circuit 
packs may be caused by 
any
 circuit pack. However, only Packet 
circuit packs can detect such problems (inasmuch as TDM-only 
circuit packs are not affected by these problems).
h. Include Packet circuit pack, port, and endpoint maintenance has been 
disabled due to more than one circuit pack reporting in-line errors. If this 
occurs more than three times in 15 minutes (that is, if maintenance is 
disabled due to errors and then re-enabled because no more errors are 
reported), a Minor alarm is raised against the Packet Bus. Note that this 
error may still be present in the error log even if the "Circuit Pack Audit 
Test" reports that only one circuit pack has indicated a problem. This 
occurs if more than one circuit pack reported errors with in any one minute 
interval since the Packet Bus fault occurred.
NOTE:
Because alarms against a Maintenance Object are not resolved until 
all alarming has been cleared, an alarm due to a missing 
Maintenance/Test Packet Bus must be cleared by installing a 
Maintenance/Test circuit pack before it can be determined if other 
Packet Bus alarms have been resolved.
i. The Maintenance/Test Packet Bus port for this port network is not in 
service. This error appears only in a High or Critical Reliability system, and 
it can occur in the following cases:
Aux Data
Packet Circuit 
Pack
Maint/Test 
Circuit Pack
Packet 
Control
1/1001
X
2/1002
X
3/1003
X
X
4/1004
X
5/1005
X
X
6/1006
X
X
7/1007
X
X
X