Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1114
PMS-LINK (Property Management System Link)
10
Link Retry Test (#215)
This test sends a message to the PMS software process to make a data call to
the extension where the PMS device connects. If the PMS Link is already up, then
this test passes without making any data call.
the extension where the PMS device connects. If the PMS Link is already up, then
this test passes without making any data call.
FAIL
Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
PASS
The PMS Link is torn down.
Table 10-328.
TEST #215 Link Retry Test
Error
Code
Test
Result
Description/ Recommendation
10
20
20
ABORT
Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
30
ABORT
Internal System Error.
1. Refer back to the
section for resolution.
1010
ABORT
The PMS Link has been busied out and placed in the
out-of-service state.
out-of-service state.
1. Enter
release pms-link
command to release the
PMS Link from busyout state.
2. Retry
test pms
command to execute the test.
Continued on next page
Table 10-327.
TEST #213 Link Tear Down Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page