Maintenance Object Repair Procedures
Page 10-1119
PMS-PRNT/JNL-PRNT (PMS Printer Link)
10
data module, and the printer device. Enter
status data <extension>
and
verify that the data extension of the printer device is in the in-service/idle
state. If the data extension is not available, then refer to the
state. If the data extension is not available, then refer to the
section for resolution.
d. Link idle timer; link comes down. This error indicates that the printer
device is in an off-line state, for example, paper jam or paper out for a
printer device. Check the printer device and act promptly to put it back to
on-line state. Enter
printer device. Check the printer device and act promptly to put it back to
on-line state. Enter
test journal wakeup-log|pms-log
command to set up
the printer link.
System Technician-Demanded Tests:
Descriptions and Error Codes
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
inspecting errors in the system. By clearing error codes associated with the
Link
Retry Test
, for example, you may also clear errors generated from other tests in
the testing sequence.
Link Tear Down Test (#213)
This test is destructive.
This test disconnects the existing link between the system and the external
printer device. If the link has been disconnected already, this test just returns
PASS. All resources allocated for a PMS Printer Link are released after this test.
printer device. If the link has been disconnected already, this test just returns
PASS. All resources allocated for a PMS Printer Link are released after this test.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
Link Tear Down Test (#213)
X
D
Link Retry Test (#215)
X
X
ND
Table 10-330.
TEST #213 Link Tear Down Test
Error
Code
Code
Test
Result
Description/ Recommendation
40
ABORT
Internal system error
50
ABORT
Internal system error
1. Retry the command at 1minute intervals a maximum of 5 times.
Continued on next page