DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1144
PR-MAINT (Maintenance Processor [TN790 RISC Systems]) 
10
MTP Analog Loop Around Test (#103)
This test is a nondestructive test. The test does a loop around by using the MTP 
INADS channel. Test data is sent through the modem out toward the INADS 
trunk. The data is looped around before the actual trunk, and it comes back into 
the on-board modem. The data is then verified for integrity. The internal modem 
is tested when the internal modem is selected. The external modem is tested 
when the external modem is selected.
When an external modem is administered in place of the internal modem, the test 
loops data in the MTP DUART ahead of the connection to the external modem. 
This test also causes the MTP DUART to verify that 
Clear-To-Send (CTS)
 is 
being supplied by the modem.
FAIL
MTP reported test failure. No loop current detected. The following steps 
apply to either an internal or external modem ( Some additional steps 
apply to an external modem only).
1. Retry at 1-minute intervals a maximum of 5 times.
2. For an external modem, if the test continues to fail:
a. If Test #230 failed, use the external modem recommendations 
listed in Test #230.
b. If Test #230 passes, the MTP most likely received a NO DIAL TONE 
response to the ATD command sent from the MTP. This problem is 
between the modem and the INADS trunk.
3. Examine the INADS trunk for connectivity, and manually check for loop 
current.
4. If there is no INADS trunk, this test should be disabled. To disable the 
test, issue the 
change system-parameters maintenance
 command, 
and change the Test Remote Access Port field to ‘‘n.’’
5. If the INADS trunk checks out okay, but the test still fails, check the 
backplane connector wiring.
6. If the backplane wiring checks out okay, replace the Processor circuit 
pack.
PASS
MTP detected a loop current on the remote access port.
1. If the system cannot call INADS, or INADS cannot contact the system, 
check with the local Central Office for problems with the INADS trunk, 
and verify that the INADS number is correct. Approved external 
modems with factory default settings are expected to work if 
administered correctly using the 
change system-parameters
 
command.
Table 10-337.
TEST #102 MTP Outpulse Relay Test  — 
Continued
Error 
Code
Test Result
Description/ Recommendation
Continued on next page