Maintenance Object Repair Procedures
Page 10-1173
PR-MEM (TN790 RISC Memory)
10
Memory Burst Read Test (#908)
This test verifies that the Memory Burst Read function works properly on the
Processor circuit pack.
Processor circuit pack.
Table 10-356.
TEST #908 Memory Burst Read Test
Error
Code
Code
Test
Result
Description/ Recommendation
100
ABORT
The test did not complete within the allowable time period.
1. Retry the command.
1022
1335
2500
1335
2500
ABORT
Internal system error
1. Retry the command.
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
error codes.
1 - 7
FAIL
The Burst Read circuit is not functioning properly.
1. If the test fails, replace the Processor and retry the test.
PASS
The Burst Read portion of the Processor circuit pack is operating
correctly.
correctly.