Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1228
SHDW-CIR (Common Shadow Circuit) 
10
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order they are presented in the table below. By 
clearing error codes associated with the 
Duplication Interface Circuit Pack Status 
Query Test,
 for example, you may also clear errors generated from other tests in 
the testing sequence.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
Table 10-383.
Common Shadow Circuit Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test duplication 1C sh r 1
1
Common Shadow 
Circuit Loop Back Test 
(#283)
MAJOR
ON
test duplication 1C r 3
257
Any
Common Shadow 
Circuit Time-Out Query 
Test (#285)
MAJOR
OFF
test duplication 1C l r 3
513
1,2
Common Shadow 
Circuit Address 
Decoder Test (#284)
MAJOR
ON
test duplication 1C r 3
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Duplication Interface Circuit Pack Status Query Test 
(#315) (a)
X
X
ND
Duplication Interface Circuit Pack Sanity Circuit Test 
(#273) (a)
X
D
Duplication Interface Circuit Pack Sanity Maze Test 
(#277) (a)
X
X
ND
Duplication Interface Circuit Pack SPE A Loop Back Test 
(#275) (a)
X
X
ND
Duplication Interface Circuit Pack SPE B Loop Back Test 
(#276) (a)
X
X
ND
Continued on next page