DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1255
STBY-SPE (Standby SPE) 
10
STBY-SPE (Standby SPE)
A high or critical reliability system contains two switch processing elements 
(SPEs). The first such element is known as the Active SPE. The Active SPE is 
currently responsible for all call processing, administration, and maintenance 
activities that are being performed by the system. The other SPE is known as the 
Standby SPE. The Standby SPE becomes the Active SPE whenever the current 
Active SPE fails. The Standby SPE does not perform call processing or 
administration activities. However, it does perform maintenance activities, but 
these activities are carried out completely under the direction of the Active SPE in 
order to monitor and maintain the health of the Standby SPE.
NOTE:
Verify that the Standby SPE is functional (no duplication alarms exist and 
the SPE has returned to the Standby Mode) by running the 
status 
system 1
 command. If the standby SPE is in the maint/idle mode with no 
standby alarms, use the 
standby refresh
 command to put the standby SPE 
into the standby mode. Verify the results by using the 
status system 1
 
command.
The Standby SPE is always in one of three modes: Standby, Maintenance, or 
Down. Usually, the Standby SPE is in Standby Mode. In this mode,
1. The Switch Control (SW-CTL) on the Standby SPE Network Control circuit 
pack is isolated from the TDM Bus so that it does not interfere with 
attempts by the Switch Control on the Active SPE Network Control circuit 
pack to control the TDM Bus
2. The Standby SPE (PKT-CTRL) Packet Control circuit pack is isolated from 
the Packet Bus to prevent interference with the activity on the Active SPE 
Packet Control circuit pack
3. The Standby SPE (PROCR) Processor is held in a reset state so that it 
does not run software
4. The 12 volt power supply on the Standby SPE Network Control circuit pack 
(TN777B) can not be turned on when the Standby SPE Processor is held 
in the reset state
5. Standby SPE Memory (MEMORY in a 386) is shadowed from Active SPE 
Memory. This means that Standby SPE Memory is updated to reflect every 
change in Active SPE Memory (for example, calls and administration 
changes).
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
Full Name of MO
STBY-SPE
WARNING
status system 1
Standby SPE
STBY-SPE
MAJOR
test spe-standby
Standby SPE