Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-4
busyout board 
8
Output
For the following output example, the command "busyout access-endpoint 
22502" was entered. Assume that the access endpoint ports for extension 22502 
are in cabinet 1, carrier C, slot 11, circuit 1 to 6.
Feature Interactions
If there is an active call on the specified access endpoint, the busyout command 
will cause the call to drop. This command is destructive.
busyout board
This command will busyout each maintenance object on the specified board.
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance 
object that is being busied out.
Maintenance Name
The type of maintenance object that is being busied out. For 
wideband access endpoint the maintenance name for each port 
is "WAE-PORT.” For single port access endpoint the maintenance 
name is "TIE-DS1."
Alt. Name
The alternate way of identifying the maintenance object. This field 
contains the extension number of the access endpoint.
Result
An indicator as to whether the object is successfully busied out. 
The possible values are: PASS, FAIL and ABORT.
Error Code
A system-generated number that tells why the busyout failed or 
aborted. A detailed list of the codes can be in the 
"Busyout/Release Error Codes" section of this chapter.
 
 busyout access-endpoint 22502                        SPE A
                            COMMAND RESULTS
   Port    Maintenance Name  Alt. Name   Result       Error Code
   01C1101   WAE-PORT        22502       PASS
   01C1102   WAE-PORT        22502       PASS
   01C1103   WAE-PORT        22502       PASS
   01C1104   WAE-PORT        22502       PASS
   01C1105   WAE-PORT        22502       PASS
   01C1106   WAE-PORT        22502       PASS
 Command Successfully Completed