555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1298
STRAT-3 (Stratum 3 Clock)]
10
NOTE:
When looking in the Stratum 3 cabinet, "A" card is on the left and "B" card is
on the right.
When looking in the Stratum 3 cabinet, "A" card is on the left and "B" card is
on the right.
Hardware Error Log Entries and Test to Clear
Values
Values
Notes:
a. In the context of the Stratum 3 clock, an OFF-BOARD alarm occurs when
there is a DS1 facility problem; otherwise, the alarm is ON-BOARD
indicating that there is a fault in the Stratum 3 clock or in the connection
between the Stratum 3 clock and the PBX (Private Branch Exchange)
switch. If the Stratum 3 clock cannot be referenced, and therefore the
indicating that there is a fault in the Stratum 3 clock or in the connection
between the Stratum 3 clock and the PBX (Private Branch Exchange)
switch. If the Stratum 3 clock cannot be referenced, and therefore the
1.
Composite Clock source refers to the protocol used to electrically transfer timing from
the Stratum 3 clock to the PBX switch. The Composite Clock source is not relevant to
Definity Generic 1.1.
the Stratum 3 clock to the PBX switch. The Composite Clock source is not relevant to
Definity Generic 1.1.
1.
Run the Short Test Sequence. Refer to the appropriate test description and follow the recommended procedures.
Stratum 3 Clock Error Log Entries
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm Level
On/Off
Board
Board
Test to Clear Value
0
1
0
Any
Any
Any
test synchronization r 4
1 (d)
Any
Stratum 3 Clock
Alarm Query (#649)
Alarm Query (#649)
MINOR
OFF
test synchronization r 4
257 (e)
Any
Stratum 3 Clock
Alarm Query (#649)
Alarm Query (#649)
MINOR
OFF
test synchronization r 4
257 (c)
None
WARNING
ON
513 (f)
Any
Stratum 3 Clock
Alarm Query (#649)
Alarm Query (#649)
MINOR
ON
test synchronization r 4
769 (g)
Any
Stratum 3 Clock
Alarm Query (#649)
Alarm Query (#649)
MINOR
ON
test synchronization r 4
1025 (h)
Any
Stratum 3 Clock
Alarm Query (#649)
Alarm Query (#649)
MINOR/ MAJOR(a)
ON
test synchronization r 4
1281 (i)
Any
Stratum 3 Clock
Alarm Query (#649)
Alarm Query (#649)
MINOR/ MAJOR(a)
ON
test synchronization r 4
1537 (b)
none
MINOR/ MAJOR(a)
ON