Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1377
TAPE-DAT (Tape Consistency) 
10
TAPE-DAT (Tape Consistency)
In High and Critical Reliability systems, the system software translations, as well 
as other information, can be stored on two tapes: one in the Active SPE and one 
in the Standby SPE. In order to flag a problem when these tapes become 
mismatched, Tape Consistency monitors the translations, announcements, 
update files, and software vintage number on both tapes in a High or Critical 
Reliability PPN system. If the translation time stamp, announcement time stamp, 
and update file time stamp and identifiers on the two tapes are not the same 
and/or if the software vintage numbers do not match, an alarm is raised. The 
software vintage can be displayed via the 
list configuration software-vintage
 
command. The Tape Consistency Test is run on system technician command 
and once a week as part of daily Standby SPE maintenance. Tape Consistency 
does not apply and does not exist in Standard systems.
Error Log Entries and Test to Clear Values
Notes:
a. An "8" in the log refers to carrier A and a "16" refers to carrier B. The Aux 
Data field records which SPE was active at the time the Tape Consistency 
Test failed.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command 
to Run
Full Name of MO
TAPE-DAT
MINOR
test tape a|b l
 Tape Consistency
Table 10-418.
Tape Consistency Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test tape a/b l
8 or 16
8 or 16
Tape Consistency 
Test (#421)
WARNING
OFF
test tape a/b l
1-7,
9-15,
8 or 16
Tape Consistency 
Test (#421)
MINOR
OFF
 test tape a/b l
17-86