Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1377
TAPE-DAT (Tape Consistency)
10
TAPE-DAT (Tape Consistency)
In High and Critical Reliability systems, the system software translations, as well
as other information, can be stored on two tapes: one in the Active SPE and one
in the Standby SPE. In order to flag a problem when these tapes become
mismatched, Tape Consistency monitors the translations, announcements,
update files, and software vintage number on both tapes in a High or Critical
Reliability PPN system. If the translation time stamp, announcement time stamp,
and update file time stamp and identifiers on the two tapes are not the same
and/or if the software vintage numbers do not match, an alarm is raised. The
software vintage can be displayed via the
as other information, can be stored on two tapes: one in the Active SPE and one
in the Standby SPE. In order to flag a problem when these tapes become
mismatched, Tape Consistency monitors the translations, announcements,
update files, and software vintage number on both tapes in a High or Critical
Reliability PPN system. If the translation time stamp, announcement time stamp,
and update file time stamp and identifiers on the two tapes are not the same
and/or if the software vintage numbers do not match, an alarm is raised. The
software vintage can be displayed via the
list configuration software-vintage
command. The Tape Consistency Test is run on system technician command
and once a week as part of daily Standby SPE maintenance. Tape Consistency
does not apply and does not exist in Standard systems.
and once a week as part of daily Standby SPE maintenance. Tape Consistency
does not apply and does not exist in Standard systems.
Error Log Entries and Test to Clear Values
Notes:
a. An "8" in the log refers to carrier A and a "16" refers to carrier B. The Aux
Data field records which SPE was active at the time the Tape Consistency
Test failed.
Test failed.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
MO Name (in
Alarm Log)
Alarm Level
Initial Command
to Run
Full Name of MO
TAPE-DAT
MINOR
test tape a|b l
Tape Consistency
Table 10-418.
Tape Consistency Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test tape a/b l
8 or 16
8 or 16
Tape Consistency
Test (#421)
Test (#421)
WARNING
OFF
test tape a/b l
1-7,
9-15,
8 or 16
Tape Consistency
Test (#421)
Test (#421)
MINOR
OFF
test tape a/b l
17-86