Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1388
TDMODULE (Trunk Data Module)
10
TDMODULE (Trunk Data Module)
The TDMODULE (Trunk Data Module) Maintenance documentation is covered in
the PDMODULE (Processor Data Module) Maintenance documentation.
the PDMODULE (Processor Data Module) Maintenance documentation.
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier where
the circuit pack is located (for example, 01, 02, ...,etc.); and pp is the 2-digit port number
(for example, 01).
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier where
the circuit pack is located (for example, 01, 02, ...,etc.); and pp is the 2-digit port number
(for example, 01).
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
Full Name of MO
TDMODULE
1
MINOR
test port PCSSpp l
Trunk Data Module
TDMODULE (a)
WARNING
test port PCSSpp l
Trunk Data Module