DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1486
TONE-BD (Tone-Clock Circuit Pack) 
10
come on and off wi thin 30 seconds. Then, all red LEDs of any 
Expansion Port Networks will come on and go off within the next 30 
seconds.
If the Tone-Clock circuit pack being replaced is in an Expansion 
Port Network, the system will reset the EPN 
(EPN cold restart)
 and 
all the red LEDs of the EPN will come on and go off within 30 
seconds.
3. If the red LEDs come on but do not go off within 30 seconds, pull the 
circuit pack out and reseat it. If the LEDs perform as expected this time, 
continue with step 6. Otherwise, there may be a problem with the TDM 
Bus; possibly a bent pin in the Tone-Clock circuit pack slot. Follow the 
directions in the TDM-BUS maintenance section.
4. If the red LEDs did light, as explained above, then go to Step 6. If the red 
LEDs do NOT light, as explained above, then go on to Step 5.
5. Restart the affected Port Network:
In the PPN, restart the system via the 
reset system 2
 command.
In an EPN, restart the EPN by resetting its Expansion Interface 
circuit pack via the 
reset board
 command, using the board 
address 1a01 for EPN1 and 1a02 for EPN2.
If this step should fail, follow normal escalation procedures.
6. Test the new Tone-Clock circuit pack to verify that it is functioning 
properly, using the 
test tone-clock PC long
 command, and verify that the 
system is operational by placing several phone calls. Where possible, try 
calls into, out from, and within the affected Port Network.
If the system is not operating properly, follow normal escalation 
procedures.
Port Networks with Two Tone-Clock Circuit 
Packs:
1. If both Tone-Clock circuit packs in a Port Network need to be replaced, 
first replace and test the one that is in standby mode. Make sure that it is 
healthy and active before replacing the second one. Make sure the 
Tone-Clock circuit pack to be replaced is in Standby Mode by displaying 
its status via the 
status port-network
 command or making sure its yellow 
LED is off.
The active/standby state of a Tone-Clock circuit pack may also be 
determined by looking at its LED. A continuously lit red LED on the 
Tone-Clock circuit pack indicates a reported fault on one or more of the