Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1583
UDS1-BD (UDS1 Interface Circuit Pack) 
10
Minor Alarm Inquiry Test (#143)
The Minor alarm raised by a UDS1 Interface circuit pack indicates that the 
average bit error rate on the DS1 facility is greater than 1/1,000,000, but less than 
1/1000. The Minor Alarm Inquiry Test is used to determine that the received DS1 
bit error rate is greater than 1/1,000,000 and less than 1/1000. When D4 framing 
mode is selected, the UDS1 Interface circuit pack takes 41 minutes to recognize 
and report a Minor alarm and 41 minutes to recognize and report that a Minor 
alarm condition has cleared. If ESF framing mode is selected, the UDS1 Interface 
circuit pack takes 10 minutes to recognize and report a Minor alarm and 10 
minutes to recognize and report that a Minor alarm condition has cleared.
When the UDS1 Interface circuit pack detects a Minor alarm condition, it will 
send a MINOR-ALARM message to the maintenance software. After the 
maintenance software receives a MINOR-ALARM message, the Minor Alarm 
Inquiry Test is initiated to confirm the Minor alarm. All trunks or ports on the circuit 
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Ensure that the board translations are correct. 
Execute the 
add ds1 PCSS
 command to administer 
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly, 
check the error log to determine whether the board 
is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the 
board.
3. If the board was found to be correctly inserted in 
step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal 
ID and the port.
Table 10-464.
TEST #142 Major Alarm Inquiry Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page