Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1596
UDS1-BD (UDS1 Interface Circuit Pack)
10
DS1 Board Loopback Test (#1209)
This test is destructive.
Table 10-468.
TEST #146 Translation Update Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
Internal System Error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL
Internal system software error.
1. Enter the
display ds1 PCSS
command to verify the
UDS1 Interface circuit pack translation.
2. If the test continues to fail, escalate the problem.
PASS
Translation data has been downloaded to the UDS1
Interface circuit pack successfully.
Interface circuit pack successfully.
0
NO
BOARD
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Ensure that the board translations are correct.
Execute the
add ds1 PCSS
command to administer
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly,
check the error log to determine whether the board
is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the
board.
is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the
board.
3. If the board was found to be correctly inserted in
step 1, then issue the
busyout board
command.
4. Issue the
reset board
command.
5. Issue the
release busy board
command.
6. Issue the
test board long
command.
This should re-establish the linkage between the internal
ID and the port.
ID and the port.
Continued on next page