Maintenance Object Repair Procedures 
Page 10-1606
UDS1-BD (UDS1 Interface Circuit Pack) 
10
CSU Repeater Loopback Test (#1211)
This test is destructive.
The CSU Repeater Loopback (RLB) Test causes a loopback at the far-edge of 
the local AT&T 120A1 CSU Module and tests the connection from the TN464F 
DS1 board to and including the CSU Module circuitry. This test will only be 
performed if the AT&T 120A1 CSU Module is present, administered, and 
connected to a 1.544 Mbps TN464F DS1 circuit pack on the back of the port 
carrier.
The test is destructive and can only be initiated by a system technician 
demanded 
test ds1-loop PCSS ds1/csu-loopback-tests
 command.
All trunks or ports on the UDS1 Interface circuit pack must be busied out via the 
system technician 
busyout board
 command before running the RLB Test.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Ensure that the board translations are correct. 
Execute the 
add ds1 PCSS
 command to administer 
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly, 
check the error log to determine whether the board 
is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the 
board.
3. If the board was found to be correctly inserted in 
step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal 
ID and the port.
Table 10-470.
TEST #1210 CSU Equipment Loopback Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page