Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-45
busyout trunk
8
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
the user to restart the command, then the following message will be displayed:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
following message will be displayed:
All maintenance resources busy; try again later
Output
For the following output example, assume that the command that was entered is
"busyout tone-clock 1a."
"busyout tone-clock 1a."
Feature Interactions
None.
busyout trunk
This command will busyout a specified trunk group or trunk group member.
Port
The tone clock maintenance object will only display the cabinet
and carrier of the desired tone/clock board.
and carrier of the desired tone/clock board.
Maintenance Name
The type of tone clock circuit pack that is being busied out which
is TONE-PT, TDM-CLK and TONE-BD.
is TONE-PT, TDM-CLK and TONE-BD.
Alt. name
Not applicable.
Result
The result of the busyout -"PASS," "ABORT," "FAIL".
Error Code
A system-generated number that tells why the busyout failed or
aborted. A detailed list of the codes can be in the
"Busyout/Release Error Codes" section of this chapter.
aborted. A detailed list of the codes can be in the
"Busyout/Release Error Codes" section of this chapter.
busyout tone-clock 1a SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01A TONE-PT PASS
01A TDM-CLK PASS
01A TONE-BD PASS
01A TONE-PT PASS
01A TDM-CLK PASS
01A TONE-BD PASS
Command successfully completed