Page 8-104
display alarms 
8
For the following output example, the 
ENTER
 key was pressed immediately after 
entering the display alarms command.
Feature Interactions
If the alarm origination is disabled via "change system-parameters maintenance," 
the "Ack?" field displays blanks no matter what the true acknowledge state is for 
the alarm.
Ack?
The columns under the “1” and “2” headings denote if the alarm 
has been acknowledged by the first and second OSS telephone 
numbers, respectively. A "y" in this field means that the alarm has 
been acknowledged. A "n" means that the alarm has not been 
acknowledged. A "c" means that the alarm resolved and cleared 
and the alarm notification was acknowledged. A blank means that 
there will be no attempt to report the alarm.
Date Alarmed
Day, hour, and minute of alarm.
Date Resolved
Day, hour, and minute of resolution. For active alarms this field will 
be zero (0).
 display alarms
 
                                  ALARM REPORT
 
 Port    Maintenance  On 
Alt    Alarm
 Svc 
Ack?  Date 
Date
         Name         Brd?  
Name   Type 
State 1 2 
Alarmed 
Resolved
 
 02A     TONE-BD      y              MAJOR         y n  05/22/20:34 00/00/00:00
 01C07   ANL-BD       y              MINOR         n n  05/22/20:26 00/00/00:00
 01C0702 ANL-LINE     n       311    WARNING  IN 
05/22/20:26 00/00/00:00
 01C0701 ANL-LINE     n       1051   WARNING  IN 
05/22/20:26 00/00/00:00
 01C0703 ANL-LINE     n       1053   WARNING  IN 
05/22/20:26 00/00/00:00
 01C1505 CO-TRK       n       78/01  WARNING  OUT 
05/22/20:26 00/00/00:00
 01C1505 CO-TRK       n       78/01  WARNING  OUT 
05/22/20:26 00/00/00:00
 02A0201 TONE-PT      n              WARNING 
05/22/20:34 00/00/00:00
 02A     TDM-CLK      n              WARNING            05/23/13:43 00/00/00:00
 PN 02B  TDM-BUS      n              WARNING            05/23/14:53 00/00/00:00
 
 
 
 