DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-156
download update-file 
8
In a High or Critical Reliability System, the connection to the INADS host 
computer may be dropped (by the INADS side) but the process of copying the 
patch file to the standby processor continues. The standby is placed in 
maintenance mode and a call placed between active and standby via the data 
channels. The file is transmitted in the same way for both tape and flash based 
systems. The same checks are made on the receiving side as were made during 
and after the original download. If no errors are found, the file is marked valid.
There is no feedback to the user on the status of the standby copy. If an error is 
encountered during the copy or validation process on the standby, an error is 
logged in the software error log. The data consistency audit will discover that the 
two patch files are inconsistent and the user must manually copy the valid file on 
the active processor to the standby processor.
The software does not indicate when the copy has completed, so scripts run by 
the TSC must not issue an immediate reset on High or Critical Reliability Systems. 
This will interrupt the copy and guarantee that the field update files on the two 
processors are inconsistent. This problem can be avoided by using one of the 
following techniques:
Use two scripts: the first to apply the patch and a second, to be run later, 
to issue the reset that applies the patch. This requires two calls to each 
duplicated switch.
Put a delay into the scripts which causes the scripts to wait a period of 
time after downloading the file and before issuing the reset. This requires 
only one call, but the amount of delay time required is not well defined as it 
depends on system load.
Use a manual means of detecting when the copy has completed: either a 
"PASS" on the data consistency audit or a match on the 
"list configuration 
software"
 form. This requires only one call and introduces less delay in 
requesting the reset.
Help Messages
There is no associated help message as the command has no options.
Error Messages
If the vintage of the standby SPE doesn’t match the vintage of the active SPE, the 
following message is displayed:
Update file vintage does not match standby SPE core vintage
If the patch identifier in the update file does not match the patch identifier in 
memory, the following message is displayed:
Update file patch identifier does not match SPE patch identifier