Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-254
monitor system 
8
Parameters
Help Messages
If the system technician presses HELP after entering "monitor system", the 
following object command word choices will be displayed:
conn         view1          view2
scr
If the system technician presses HELP after entering "monitor system conn" the 
following message will be displayed:
 Enter 3 port network numbers(xx-xx) [’pnn’ x x x]
Error Messages
If the pnn number entered is non numeric, not administered, or invalid in any 
other way, one of following messages will be displayed:
 Object command word omitted; please press HELP
 "xx" is an invalid identifier; press RETURN to execute modified command
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
 Command resources busy; Press CANCEL to clear, and then resubmit
view1
This specifies a form that will include the attendant status, the 
maintenance status, the last hour’s measurement of trunk groups, hunt 
groups, and the attendant group, and finally, the time of day.
view2
This specifies a form that will display a subset of the view1 form entries. 
This form will include all of the view1 form except the last hour’s hunt 
group measurements.
conn
This option will bring up the connection monitor output for key 
information.
entering no 
options
Omitting the "pnn # # #" argument on the command line will cause the 
default configuration of Pnn’s 1, 2 and 3 to be displayed.
pnn # # #
Entering "pnn # # #", where "#" is replaced by a pnn number from 1 to 3, 
will cause data for the specified pnns to be displayed.
entering no options
Omitting the "pnn # # #" argument on the command line will cause 
the default configuration of Pnn’s 1, 2 and 3 to be displayed.
pnn # # #
Entering "pnn # # #", where "#" is replaced by a pnn number from 
1 to 3, will cause data for the specified pnns to be displayed.