Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-317
reset board 
8
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
Command resources busy; 
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
All maintenance resources busy; try again later
Output
For the following output example, assume that the board in port network 1, carrier 
c, slot 7 is an analog board with three ports administered. The command that 
was entered is "reset board 1c07."
Feature Interactions
None.
Port
The port address (cabinet-carrier-slot) of the maintenance object 
that is being reset.
Maintenance Name
The type of maintenance object being reset.
Alt. Name
The alternate means of identifying the maintenance object. This 
field contains the extension when the object is a station, and it 
contains xxx/yyy when the object is a trunk, where xxx is the trunk 
group number and yyy is the member number. It contains P/xxx 
when the object is a private CO line, where xxx is the private CO 
line group number.
Result
The result of the reset -"PASS," "ABORT," "FAIL."
Error Code
A system-generated number that tells why the reset failed or 
aborted. A detailed list of the codes can be in the "Reset 
Commands" section of this chapter.
 
 reset board 1C07
                               TEST RESULTS
  Port    Maintenance Name    Alt. Name Test No. Result    Error Code
  01C07        ANL-BD                      53     PASS
 Command Successfully Completed