Maintenance Commands and Trouble-Clearing Aids 
Page 8-326
reset system 
8
The reset system interchange command does not disrupt in-progress calls. 
However, it drops links to local and remote administration terminals and also 
drops and re-establishes connections on the Network Control Circuit Pack data 
channels. This includes CDR and PMS links. No new calls can be made during 
the interchange, but stable calls are not affected.
When a system restart occurs with the corresponding vector bit set, a core dump 
is written to memory card, only if the memory card is the special core dump 
card), the vector is cleared, and the requested restart is performed.
All successful reset system commands will log the user off.
Defaults
None.
Parameters
llevel
The reset levels are entered numerically with a range of 1 - 5, the levels 
are as follows, and the approximate times are listed for each 
appropriate level and system configuration:
Level
Recovery
SMALL 
Flash
MEDIUM 
Flash
1
Warm Restart
2
Cold-2
3
Cold-1
4
Reboot
5
Extended Reboot
interchange
Control of the system passes to the standby SPE as the active SPE 
becomes the standby SPE and the standby SPE becomes the active 
SPE. The optional "health-override" qualifier can be entered to force an 
interchange even if the Fault Severity Level of the standby SPE would 
normally cause the maintenance software to abort the interchange. 
The Fault Severity Level of an SPE is determined by the alarmed 
components in that SPE. Each component is given a severity level, and 
the single worst alarm (severity) for a SPE defines Fault Severity Level 
for the SPE. The table below lists the maintenance objects, their 
alarms, severities and the restart level of the interchange that affect a 
SPE’s Fault Severity Level.