Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-409
status cleared-alarm-notif 
8
Output
The following is an example of the fields contained on the output form.
Feature Interactions
None.
status cleared-alarm-notif
This command returns the status of Cleared Alarm Notification.
Synopsis
status cleared-alarm-notif [1 | 2]
Examples
status cleared-alarm-notif
status cleared-alarm-notif 1
status cleared alarm-notif 2
Link State
Up, down, or extension not administered will be displayed.
Up
 means the link is up and the application can use the link. This 
is the normal state of operation.
Down
 means the link is physically down.
Extension not administered
 means you need to administer the 
system cdr feature
 form.
Number of Retries
The number of times the switch has tried to set up the link.
Maintenance Busy
Whether the maintenance object has been busied out or not. Will 
be set to either 
yes
 or 
no
.
 
 status cdr-link
                        CDR LINK STATUS
          Primary                    Secondary
        Link State: up               extension not administered
 Number of Retries: 0
  Maintenance Busy? no