Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-491
status pri-endpoint 
8
Output
The following is an example of the fields contained on the output form.
Feature Interactions
None.
status pri-endpoint
This command displays the status of a PRI endpoint.
Synopsis
status pri-endpoint extension 
print
Permissions
The following default logins may execute this command: system technician, cust, 
inads, init, nms, browse.
Physical Link State
Up, down, or extension not administered will be displayed. The 
PMS link is considered administered only if an extension is given in 
the System Hospitality form.
Protocol State
"up", "down", or blank if not administered.
Number of Retries
Number of times the switch has tried to set up the link. Only 
displayed when the link is down. The Largest number that can be 
displayed is 999.
Maintenance Busy
"yes", or "no" (that is, system technician has or has not busied out 
the link). Blank if PMS link not administered.
 
 status pms-link
                       PMS LINK STATUS
     Physical Link State: down
          Protocol State: down
       Number of Retries: 3
        Maintenance Busy? no