Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-526
status trunk
8
For the following output example, the command that was entered is "status trunk
78/1".
78/1".
GROUP Output
The following is output when a user enters only a trunk group:
Service State
Whether the trunk is in service or out of service. One of the
following states is displayed: in-service/active, in-service/idle,
out-of-service, out-of-service-NE (Near End), out-of-service-FE
(Far End), maint-NE/active, maint-FE/active, maint-NE/idle,
maint-FE/idle, pending-in-service, pending-maint, or
disconnected. NE (Near End) and FE (Far End) refer to which
"end" of the trunk has placed the facility in the state that it is in.
following states is displayed: in-service/active, in-service/idle,
out-of-service, out-of-service-NE (Near End), out-of-service-FE
(Far End), maint-NE/active, maint-FE/active, maint-NE/idle,
maint-FE/idle, pending-in-service, pending-maint, or
disconnected. NE (Near End) and FE (Far End) refer to which
"end" of the trunk has placed the facility in the state that it is in.
Maintenance Busy
Whether there is any maintenance testing being performed
upon the trunk.
upon the trunk.
CA-TSC State
The state of the temporary signaling connection. A temporary
signaling connection is a connection set up to pass call
information over PRI signaling links.
signaling connection is a connection set up to pass call
information over PRI signaling links.
Member
The trunk group number and group member number. Valid identifiers
are 1-99/1-99.
are 1-99/1-99.
Port
The port location (cabinet-carrier-slot-circuit) of the trunk.
Service State
Whether the trunk is in service or out of service. One of the following
states is displayed: in-service/active, in-service/idle, out-of-service,
out-of-service-NE (Near End), out-of-service-FE (Far End),
maint-NE/active, maint-FE/active, maint-NE/idle, maint-FE/idle,
pending-in-service, pending-maint, or disconnected. NE (Near End)
and FE (Far End) refer to which "end" of the trunk has placed the
facility in the state that it is in.
states is displayed: in-service/active, in-service/idle, out-of-service,
out-of-service-NE (Near End), out-of-service-FE (Far End),
maint-NE/active, maint-FE/active, maint-NE/idle, maint-FE/idle,
pending-in-service, pending-maint, or disconnected. NE (Near End)
and FE (Far End) refer to which "end" of the trunk has placed the
facility in the state that it is in.
Mtce Busy
Whether there is any maintenance testing being performed upon the
trunk.
trunk.
Connected Ports
Port locations (cabinet-carrier-slot-circuit) connected to the trunk.
status trunk 78/1
TRUNK STATUS
Trunk Group/Member: 078/001 Service State: in-service/idle
Port: 01C1505 Maintenance Busy? no
Signaling Group ID: CA-TSC State:
Connected Ports:
Port: 01C1505 Maintenance Busy? no
Signaling Group ID: CA-TSC State:
Connected Ports: