DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-547
test analog-testcall 
8
Help Messages
If the system technician presses 
HELP
 after entering "test analog-testcall" a 
message showing the following keywords is displayed:
trunk  board     port
If the system technician presses 
HELP
 after entering "test analog-testcall trunk," 
the following message will be displayed:
Enter group number or group number/member number,
[’full’ or ’supervision’ or   ’no-selftest’
or ’no-return-loss’ or ’no-st-or-rl’],
[’repeat 1-100’], [’schedule’]
If the system technician presses 
HELP
 after entering "test analog-testcall port" the 
following message will be displayed:
Enter trunk port number [’full’ or ’supervision’ 
or ’no-selftest’ or’no-return-loss’ 
or ’no-st-or-rl’], [’repeat 1-100’], [’schedule’]
If the system technician presses 
HELP
 after entering "test analog-testcall board" 
the following message will be displayed:
Enter trunk board number, [’full’ or ’supervision’
or ’no-selftest’ or ’no-return-loss’ 
or ’no-st-or-rl’], [’repeat 1-100’], [’schedule’]
Error Messages
If the format for the trunk location is incorrect, the following message displays:
Format invalid
If the trunk group or member range is invalid, the following message displays:
Trunk or trunk group invalid
no-st-or-rl
This will execute the "full" test, but will skip all self test and return loss 
sequences. This saves about 40 seconds on the type 105 
transmission test and will not have any effect on type 100 
transmission tests or type 102 transmission tests.
repeat number
The "number" specifies how many times each test in the sequence is 
to be repeated. "Number" may be any integer between 1 and 100.
schedule
When the "schedule" option is specified, the command is validated 
and then a scheduling form is displayed to allow the technician to 
schedule execution of the command. The command is then placed in 
the command queue and is executed at the specified time. The 
information displayed by the command is sent to the system printer 
instead of the screen. Refer to the Report Scheduler and System 
Printer feature specification [1] for more details.