DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-557
test card-mem 
8
For a duplex switch configuration, the following message will be displayed:
Enter [cabinet(1)];carrier(A-B), [’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If the SPE is not active, the following message will be displayed:
Command must be executed from active SPE
If the carrier entered is invalid, the following message will be displayed:
"entered value" is an invalid identifier;
press RETURN to execute modified command
If the NETCON board is not TN777B, the following message is displayed:
Must install TN777B circuit pack
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If the standby is entering maintenance mode when this command is executed, 
then the following message is displayed:
Cannot interrupt Standby SPE while entering
maintenance mode; please try later
If the standby SPE is not refreshed when this command is executed, then the 
following message is displayed:
Standby SPE memory not refreshed;
use the "refresh spe-standby" command.
If the standby SPE is not refreshed and the active SPE is hard selected via the 
SPE select switches when this command is executed, then the following 
message is displayed:
Active SPE locked via select switches;
Standby SPE memory not refreshed
If the standby SPE is busy with another task, then the following message is 
displayed
Standby SPE busy with another task;
for information use "status system 1"
If the standby SPE is not available when this command is executed, then the 
following message is displayed:
Standby SPE not available;
for information use "status system 1"