Maintenance Commands and Trouble-Clearing Aids 
Page 8-563
test customer-alarm 
8
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "test customer-alarm" on a 
simplex SPE system, the following message will be displayed:
Enter [cabinet(1-3)],[’long’ or ’short’],
  [’repeat’(1-100) or ’clear’], [’schedule’]
If the system technician presses 
HELP
 after entering "test customer-alarm" on a 
duplex SPE system the following message will be displayed:
For cabinet 1 enter [cabinet(1)];
carrier (A-B),[’long’ or ’short’],
  [’repeat’(1-100) or ’clear’], [’schedule’]
For cabinet 2-3 enter cabinet(2-3),[’long’ or ’short’],
  [’repeat’(1-100) or ’clear’], [’schedule’]
location
The location designates the physical position of the desired 
customer-alarm circuit pack. The location consists of a cabinet number 
and carrier letter. The cabinet number is one or two digits from 1 to 3 
with leading zeros allowed. Cabinet 1 is the PPN with 2-3 referring to 
some optional EPN. The carrier is either "a" or "b" for cabinet 1 for SPE 
duplex systems. For SPE simplex systems, when selecting cabinet 1, 
the carrier must be "a" if entered. For cabinets 2-3, the carrier must be 
"a" if entered.
short
This will cause test number 115 to run.
long
This will cause test number 115 to run and is the same as the short 
sequence.
repeat number
The "number" specifies how many times each test in the sequence is to 
be repeated. "Number" may be any integer between 1 and 100.
clear
This option causes the test sequence (short or long) to repeat until the 
alarm (if one exists against the maintenance object) is cleared or a 
single test in the sequence fails. If no alarms are registered against the 
maintenance object then the test sequence will be exercised only 
once. The clear option forces a clear of all alarms if no errors are 
encountered during testing.
schedule
When the "schedule" option is specified, the command is validated and 
then a scheduling form is displayed to allow the technician to schedule 
execution of the command. The command is then placed in the 
command queue and is executed at the specified time. The 
information displayed by the command is sent to the system printer 
instead of the screen. Refer to the Report Scheduler and System 
Printer feature specification [1] for more details.