Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-575
test duplication-interface 
8
Cannot interrupt Standby SPE while entering
maintenance mode; please try later
If the standby SPE is not refreshed when this command is executed, then the 
following message is displayed:
Standby SPE memory not refreshed; 
use the "refresh spe-standby" command.
If the standby SPE is not refreshed and the active SPE is hard selected via the 
SPE select switches when this command is executed, then the following 
message is displayed:
Active SPE locked via select switches;
Standby SPE memory not refreshed
If the standby SPE is busy with another task, then the following message is 
displayed:
Standby SPE busy with another task;
for information use "status system 1"
If the standby SPE is not available when this command is executed, then the 
following message is displayed:
Standby SPE not available;
for information use "status system 1"
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
Output
The responses will be displayed on a test-by-test basis with one line of data 
displayed for each test result.
Port
The port address (cabinet-carrier) will always be 01A or 01B.
Maintenance Name
The maintenance name will always be SHDW-CIR, SPE-SELE, or 
DUPINT.
Alt. Name
Not applicable.
Test No.
The actual test that is being executed.
Result
The result of the individual test -"PASS," "ABORT," "FAIL," "NO 
BOARD," "DISABLED."
Error Code
A system-generated number that tells why the test failed or 
aborted. A detailed list of the codes according to "Test No." is 