Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-597
test interface 
8
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
All maintenance resources busy; try again later
Output
If the test passed then the following message will be displayed:
Command successfully completed
If the test failed, because the link was up or because there was an active alarm 
that the switch needs to report or there was a problem with the call, the following 
message will be displayed:
Command failed
NOTE: An entry is made in the error log describing why the inads-link test failed.
Feature Interactions
None.
test interface
This command will test a processor interface board.
Synopsis
test interface location 
[ short | long ][ repeat number | clear ] schedule
Permissions
The following default logins may execute this command: system technician, 
inads, init, nms.