Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-602
test isdn-testcall
8
Permissions
The following default logins may execute this command: system technician,
inads, init.
inads, init.
Examples
test isdn-testcall 80/1
test isdn-testcall 80/1 schedule
test isdn-testcall 78/2 minutes 10
test isdn-testcall 78/3 minutes 100 schedule
test isdn-testcall 80/1 schedule
test isdn-testcall 78/2 minutes 10
test isdn-testcall 78/3 minutes 100 schedule
Description
The test isdn-testcall command starts an outgoing ISDN-PRI test call in the
asynchronous method. The trunk to originate the ISDN-PRI test call from is
specified. If the test results are "PASS" the test call is started. A test result of
"ABORT" means that a resource wasn’t available (i.e. B-channel,
Maintenance/Test circuit pack). A test result of "FAIL" denotes that the outgoing
ISDN-PRI test call was not established.
asynchronous method. The trunk to originate the ISDN-PRI test call from is
specified. If the test results are "PASS" the test call is started. A test result of
"ABORT" means that a resource wasn’t available (i.e. B-channel,
Maintenance/Test circuit pack). A test result of "FAIL" denotes that the outgoing
ISDN-PRI test call was not established.
Defaults
The duration of the test call defaults to 8.4 or 9.6 seconds.
Parameters
Help Messages
If the system technician presses
HELP
after entering "test isdn-testcall" the
following message will be displayed:
Enter group #/member # [’minutes’ (1-120)],
[’schedule’]
group number
The group number is an administered number associated with each
trunk group.
trunk group.
member number
The member number is an administered number identifying a
particular trunk within a trunk group.
particular trunk within a trunk group.
minute number
The duration of the test call specified in minutes (1-120).
schedule
When the "schedule" option is specified, the command is validated
and then a scheduling form is displayed to allow the technician to
schedule execution of the command. The command is then placed
in the command queue and is executed at the specified time. The
information displayed by the command is sent to the system printer
instead of the screen. Refer to the Report Scheduler and System
Printer feature specification [1] for more details.
and then a scheduling form is displayed to allow the technician to
schedule execution of the command. The command is then placed
in the command queue and is executed at the specified time. The
information displayed by the command is sent to the system printer
instead of the screen. Refer to the Report Scheduler and System