Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-605
test journal-printer 
8
Only one ISDN trunk can be tested per port network at a time. Once testing is 
completed, another ISDN trunk can be tested in that port network.
The maximum number of asynchronous outgoing test calls running, depends on 
the number of Maintenance/Test circuit packs in the system.
test journal-printer
This command will perform tests on the journal printer links.
Synopsis
test journal-printer [ pms-log | wakeup-log ] 
[ short | long ][ repeat number | clear 
] schedule
Permissions
The following default logins may execute this command: system technician, 
inads, init.
Examples
test journal-printer pms-log l 
test journal-printer pms-log l schedule
test journal-printer wakeup-log r 2
test journal-printer wakeup-log r 2 schedule
test journ pm r 3
test journ pm r 3 schedule
Description
The test journal-printer command will perform hardware diagnostics on the link 
between the switch and one of the technician specified journal printer links. 
There are two types of journal printer links (pms-log wakeup-log).
For general information on journal printer links, see the second paragraph in the 
"Description" section of the "busyout pms-link" manual pages.
For information on what a journal printer is and does, see the second paragraph 
in the 
 section of the 
 manual pages.
Defaults
The default for the command is short with the repeat of 1.