Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-609
test led 
8
The following LEDs are NOT lighted by the test led command:
SPE Select LEDs on the Duplication Interface Circuit Packs.
Power Unit LEDs.
The yellow (amber) LED on the tape drive.
Defaults
The default for the command is "all" with a repeat of 1 and short in a duplex 
system.
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "test led" the following 
message will be displayed:
Enter [’all’ or ’cabinet’ (1-3)],
[’long’ or ’short’ ], [’repeat’ (1-100)]
Error Messages
If there is an error in the input to the command, where "x" is the invalid input, the 
following message will be displayed:
"x" is an invalid identifier; 
press RETURN to execute modified command
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
all
All LEDs in all carriers will be tested.
cabinet number
The number of the cabinet that will be tested. Each carrier in the 
cabinet will complete testing before the next carrier is started.
short
In a simplex system the short and long option are identical and will 
turn on and off all leds in the specified port network. In a duplex 
system, the short option will NOT affect the leds in the standby SPE 
carrier in the PPN.
long
In a simplex system the short and long option are identical and will 
turn on and off all leds in the specified port network. In a duplex 
system, the long option will affect the leds in the standby SPE carrier 
in the PPN.
repeat number
The "number" specifies how many times each test is repeated. 