Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-644
test pri-endpoint
8
Examples
test pri-endpoint 25012
test pri-endpoint 45002 sh
test pri-endpoint 45892 l
test pri-endpoint 24389 sh r 4
test pri-endpoint 34899 l r 6
test pri-endpoint 34912 l r 5 schedule
test pri-endpoint 93483 r 2
test pri-endpoint 10022 c
test pri-endpoint 92349 schedule
test pri-endpoint 45002 sh
test pri-endpoint 45892 l
test pri-endpoint 24389 sh r 4
test pri-endpoint 34899 l r 6
test pri-endpoint 34912 l r 5 schedule
test pri-endpoint 93483 r 2
test pri-endpoint 10022 c
test pri-endpoint 92349 schedule
Description
The test pri-endpoint command performs hardware diagnostic tests on all port
circuits (B-channels) that are associated with the specified PRI endpoint.
circuits (B-channels) that are associated with the specified PRI endpoint.
Defaults
The default for the command is short with repeat number of 1.
Parameters
Help Messages
If the user presses
HELP
after entering "test pri-endpoint", the following message
is displayed:
Enter extension number, [’long’ or ’short’],
[’repeat’ (1-100)], [’schedule’]
extension
The extension of the PRI endpoint to be tested. The number of digits in
an extension is determined by the dial-plan.
an extension is determined by the dial-plan.
short
This will cause the command to execute a series of nondestructive
diagnostic tests.
diagnostic tests.
long
This will execute a more comprehensive and longer version of
nondestructive diagnostic tests.
nondestructive diagnostic tests.
repeat number
The "number" specifies how many times each test in the sequence is to
be repeated. "Number" may be any integer between 1 and 100.
be repeated. "Number" may be any integer between 1 and 100.
schedule
When the "schedule" option is specified, the command is validated and
then a scheduling form is displayed to allow the technician to schedule
execution of the command. The command is then placed in the
command queue and is executed at the specified time. The
information displayed by the command is sent to the system printer
instead of the screen. Refer to the Report Scheduler and System
Printer feature specification [1] for more details.
then a scheduling form is displayed to allow the technician to schedule
execution of the command. The command is then placed in the
command queue and is executed at the specified time. The
information displayed by the command is sent to the system printer
instead of the screen. Refer to the Report Scheduler and System
Printer feature specification [1] for more details.