Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-667
test synchronization 
8
For the following output example, assume that the port in cabinet 1, carrier c, slot 
7, circuit 1 is an analog port and extension 81902 is connected to that port. The 
command that was entered was "test station 81902".
Feature Interactions
None.
test synchronization
This command updates all the boards involved with synchronization.
Synopsis
test synchronization 
[ short | long ][ repeat number | clear ] schedule
Permissions
The following default logins may execute this command: system technician, 
inads, init.
Test No
The actual test that is being executed.
Result
The result of the individual test -"PASS," "ABORT," "FAIL," "NO 
BOARD," "DISABLED," "EXTRA BD."
Error Code
A system-generated number that tells why the release failed or 
aborted. A detailed list of the codes according to "Test No." is 
provided for each MO.
 
 test station 81902 short
                             TEST RESULTS
   Port      Maintenance Name  Alt. Name Test No. Result       Error Code
   01C0701   ANL-LINE                    35       PASS
   01C0701   ANL-LINE                    48       PASS
   01C0701   ANL-LINE                    36       PASS
 Command Successfully Completed