Lucent Technologies R5SI 用户手册

下载
页码 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-7
ABRI-PORT (ASAI ISDN-BRI Port) 
10
ABRI-PORT (ASAI ISDN-BRI Port)
NOTE:
Refer to "BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI 
Port)" for repair procedures.
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier designation 
(A, B, C, D, or E); and SS is the address of the slot in the carrier where the circuit pack is 
located (01, 02, ..., and so forth); and pp is the 2-digit port number (for example, 01).
2.
The alarm level for ABRI ports may be administered using the 
set options
 command. The 
alarm level can be set independently for Off-Board and On-Board alarms to MAJOR for all 
ABRI ports in the system.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
Full Name of MO
ABRI-PORT
2
MAJOR(b)
test port PCSSpp l 
ASAI ISDN-BRI Port
ABRI-PORT 
MINOR
test port PCSSpp l 
ASAI ISDN-BRI Port