Maintenance Object Repair Procedures 
Page 10-46
ANL-16-L (16-Port Neon Analog Line) 
10
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. This is an in-line error and can only be resolved over time. This indicates 
that no terminal equipment was present when ringing was attempted. 
Execute the short 
test port PCSSpp
 command, and follow the procedure 
for the results of Test #48.
40960
indicates that too many simultaneous incoming ringing 
attempts were made on this board. Only four ports on a board may 
be ringing simultaneously. A fifth incoming call will cause an inline 
error from the board.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test 
description and follow the recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the 
set options
 
command.
Table 10-19.
16-Port Neon Analog Line Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
40960 
40977
none
15 (b)
Any
Audits and Updates 
Test (#36)
18
0
busyout station 
<extension>
WRN
ON
release station <extension>
130 (c)
None
WRN
ON
test port PCSSpp sh
257 (d)
40973
none
513 (e)
Station Present Test 
(#48)
WRN
OFF
test port PCSSpp sh r 2
769
Battery Feed Test 
(#35)
MIN/WRN
2
ON
test port PCSSpp sh r 2
1025
Loop Around Test 
(#161)
MIN/WRN
2
ON
test port PCSSpp l r 2
1281
Conference Test (#7)
MIN/WRN
2
ON
test port PCSSpp l r 2
1537
NPE Crosstalk Test 
(#6)
MIN/WRN
2
ON
test port PCSSpp l r 2