DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-50
ANL-16-L (16-Port Neon Analog Line) 
10
Conference Circuit Test (#7)
One or more NPEs reside on each circuit pack with a TDM Bus interface. The 
NPE controls port connectivity and gain, and provides conferencing functions on 
a per-port basis. The Conference Circuit Test verifies that the NPE channel for 
the port being tested can correctly perform the conferencing function. The NPE is 
Any
FAIL
This test can fail due to on-board or off-board problems. Off-board 
problems of concern include EXP-INTF faults, TDM-BUS faults, and faults 
associated with the tone detectors/tone generators. Clear all off-board 
problems before replacing the board. Keep in mind that a TDM-BUS 
problem is usually the result of a faulty board connected to the backplane 
or bent pins on the backplane.
1. Look for EXP-INTF errors in the error log. If present, refer to the 
EXP-INTF Maintenance documentation.
2. Look for TDM-BUS errors in the error log. If present, refer to the 
TDM-BUS Maintenance documentation.
3. Look for TONE-BD and/or TONE-PT errors in the error log. If present, 
refer to the TONE-BD Maintenance documentation and the TONE-PT 
Maintenance documentation.
4. Test the board when the faults from steps 1, 2, and 3 are cleared. 
Replace the board only if the test fails. 
PASS
The port is correctly using its allocated time slots. User-reported troubles 
on this port should be investigated by using other port tests, by examining 
station wiring, or by examining the station.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
list 
config
 command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should re-establish the 
linkage between the internal ID and the port. If this is not the case, 
dispatch to check to ensure that there is a valid board inserted.
Table 10-20.
TEST #6 NPE Crosstalk Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page