Renesas PLQP0176KB-A 用户手册

下载
页码 38
 
Section 3   Connection Procedures 
3.1 
Connecting User System Interface Board to User System 
WARNING
 
   
Always switch OFF the user system and the emulator  
  product before the USER SYSTEM INTERFACE BOARD  
  is connected to or removed from any part.  Before  
  connecting, make sure that pin 1 on both sides are correctly  
  aligned.  Failure to do so will result in a FIRE HAZARD and  
  will damage the user system and the emulator product or  
  will result in PERSONAL INJURY.  The USER PROGRAM will  
 be LOST. 
To connect the cable head to the user system, follow the instructions below. 
3.1.1 
Installing IC Socket 
Solder the IC socket for a PLQP0176KB-A package to the user system. 
CAUTION
 
   
Be sure to completely solder the leads so that the solder  
  slops gently over the leads and forms solder fillets. (Use  
  slightly more solder than the MCU.)