Fujitsu P3NK-4452-01ENZD 用户手册

下载
页码 614
XG Series User's Guide
Chapter 5 Command Reference
Port Information Settings
105
5.1.1.15 ether recovery limit
Function
Set the upper limit number of linkdown times.
Available Model
XG0224 / XG0448 / XG2600
Syntax
ether <number> recovery limit <limit>
Options
<number>
ether port number
Set a port number to use with a decimal value.
When setting multiple port numbers, separate them with commas (,).
When setting sequential numbers, separate them with hyphens (-). (Example: "1-8")
<limit>
Number of linkdown times
Set the upper limit number of linkdown times, for the ports to go offline, with a decimal 
value from 1 to 10.
Use Mode
Configuration mode (admin class)
Explanation
Set the number of times for linkdown as the upper limit for the relevant ports to go offline. 
When the upper limit has been exceeded, the log is output to the SYSLOG and the ports 
are offline.
Caution
If ports are offline, release them with the 
 command with port releasing.
When offline ports are released by with 
 command, the number of times for 
linkdown is reset to zero again.
Default
The ports are not offline during linkdown, assuming that there is no upper limit.