Freescale Semiconductor MC68HC908MR32 用户手册

下载
页码 282
Clock Generator Module (CGM)
MC68HC908MR32 • MC68HC908MR16 Data Sheet, Rev. 6.1
66
Freescale Semiconductor
4.5.1  PLL Control Register 
The PLL control register (PCTL) contains the interrupt enable and flag bits, the on/off switch, and the base 
clock selector bit.
PLLIE — PLL Interrupt Enable Bit 
This read/write bit enables the PLL to generate an interrupt request when the LOCK bit toggles, setting 
the PLL flag, PLLF. When the AUTO bit in the PLL bandwidth control register (PBWC) is clear, PLLIE 
cannot be written and reads as logic 0. Reset clears the PLLIE bit.
1 = PLL interrupts enabled
0 = PLL interrupts disabled
PLLF — PLL Interrupt Flag 
This read-only bit is set whenever the LOCK bit toggles. PLLF generates an interrupt request if the 
PLLIE bit also is set. PLLF always reads as logic 0 when the AUTO bit in the PLL bandwidth control 
register (PBWC) is clear. Clear the PLLF bit by reading the PLL control register. Reset clears the PLLF 
bit.
1 = Change in lock condition
0 = No change in lock condition
NOTE
Do not inadvertently clear the PLLF bit. Any read or read-modify-write 
operation on the PLL control register clears the PLLF bit. 
PLLON — PLL On Bit
This read/write bit activates the PLL and enables the VCO clock, CGMVCLK. PLLON cannot be 
cleared if the VCO clock is driving the base clock, CGMOUT (BCS = 1). See 
. Reset sets this bit so that the loop can stabilize as the MCU is powering up.
1 = PLL on
0 = PLL off
BCS — Base Clock Select Bit
This read/write bit selects either the crystal oscillator output, CGMXCLK, or the VCO clock, 
CGMVCLK, as the source of the CGM output, CGMOUT. CGMOUT frequency is one-half the 
frequency of the selected clock. BCS cannot be set while the PLLON bit is clear. After toggling BCS, 
it may take up to three CGMXCLK and three CGMVCLK cycles to complete the transition from one 
source clock to the other. During the transition, CGMOUT is held in stasis. See 
. Reset clears the BCS bit.
1 = CGMVCLK divided by two drives CGMOUT
0 = CGMXCLK divided by two drives CGMOUT
NOTE
PLLON and BCS have built-in protection that prevents the base clock 
selector circuit from selecting the VCO clock as the source of the base clock 
Address:
$005C
Bit  7
6
5
4
3
2
1
Bit  0
Read:
PLLIE
PLLF
PLLON
BCS
1
1
1
1
Write:
R
R
R
R
R
Reset:
0
0
1
0
1
1
1
1
R
= Reserved
Figure 4-5. PLL Control Register (PCTL)